Motion and orientation​

SensorMeasurement rangePrecision and noiseVibration / operating notes
Bosch BMI088 IMUAccelerometer: up to ±24 g. Gyroscope: up to ±2000 °/s.16-bit output. Typical noise density: 175 µg/√Hz (acceleration), 0.014 °/s/√Hz (angular rate).Designed for high vibration suppression and vibration robustness in drones and robotics.
MEMSIC MMC5983MA magnetometer±8 gauss on each axis.Up to 18-bit output; typical 0.4 mG RMS noise at the lowest bandwidth setting.Heading accuracy is affected by nearby current-carrying components and wiring.
Infineon DPS368 barometer (optional)300-1200 hPa.Typical absolute accuracy: ±1 hPa; relative accuracy: ±0.06 hPa; high-precision noise: 0.002 hPa RMS.Relative accuracy applies over a 1 hPa change at 800-1200 hPa and constant temperature of 20-60 °C.

Sources: Bosch BMI088 specifications, MEMSIC MMC5983MA datasheet, Infineon DPS368 datasheet.

Compass placement

Current flowing through nearby components and wiring creates magnetic fields that affect compass accuracy. With the same placement and wiring, a few amps generally cause less interference than tens of amps; distance and wire routing also matter. For high-current installations, use an external compass mounted away from motors, ESCs, and power wiring. See ArduPilot's compass interference guidance.

Voltage monitoring​

Five voltage readings monitor the board's supplies and external power inputs.

Battery
Maximum voltageUp to 26 V
Multiplier11×

Measures the dedicated battery-sensing input.

Servo rail
Maximum voltageUp to 9 V
Multiplier6.6×

Monitors the shared VCC supply for the PWM and flexible headers.

Peripheral supply
Nominal voltage5 V rail
Multiplier6.6×

Monitors the regulated supply used by the serial and GNSS connectors.

MCU supply
Nominal voltage3.3 V rail
Multiplier1×

Monitors the internal logic supply.

CAN power
ConnectionSense only
Multiplier6.6×

Measures the voltage on the CAN power pin. The board neither supplies bus power nor draws its own power from this pin.

Firmware configuration

Multiply the measured ADC voltage by the listed multiplier to obtain the monitored voltage. Check whether the firmware already applies this scaling before setting a multiplier, and calibrate the reading against a multimeter. See ports and pinout for connector wiring and supply information.